Bending Beam Load Cell

Offering you a complete choice of products which include bending beam load cell, beam type load cell in ahmedabad, bending beam load cells and beam type load cell.

Bending Beam Load Cell

Request Callback

₹ 2300 / Piece Get Latest Price

Product Brochure
Load Capacity200 kg
TypeBending Beam
MaterialAlloy Steel
Ingress ProtectionIP68
ModelKP919
Load Cell CertificationsOIML
Output Sensitivity(FS)2.0 +/- 0.002 mV/V

RATED LOAD (KG) 10, 20, 30, 50, 100, 200, 300, 500

Precision C2/C3

Output Impedance(Ω) 350 + 5

 Composition Error 0.03/0.02

Insulation (MΩ) > 20000

Rated Output(mv/v) 3.0 + 0.2

 Excitation Voltage(V) 5~15(DC)

Non-Linearity (%FS) 0.025

Compensated Temp.(˚C) -10~+50

 Hysteresis (%FS) 0.02

 Use Temp. (˚C) -20~+60

 Repeatability (%FS) 0.02/0.01

 Temp. Effect on Span(%FS) 0.02

 Creep (%FS) 0.03/0.02

Temp. Effect on Zero(%FS) 0.02

 Zero Balance (%FS) + 1.0

Safe Overload(%FS) 120

 Input Impedance(Ω) 400 + 10

 Ultimate Overload(%FS) 150

Beam Type Load Cell In Ahmedabad

Request Callback

₹ 3200 / Piece Get Latest Price

Product Brochure
Load Capacity5kg
TypeCompression
MaterialAlloy Steel
ApplicationElectronics Scale
Load Cell Intervals (nLC)/Divisions4000
Packaging TypeBox

RATED LOAD (KG) 10, 20, 30, 50, 100, 200, 300, 500

Precision C2/C3

Output Impedance(Ω) 350 + 5

 Composition Error 0.03/0.02

Insulation (MΩ) > 20000

Rated Output(mv/v) 3.0 + 0.2

 Excitation Voltage(V) 5~15(DC)

Non-Linearity (%FS) 0.025

Compensated Temp.(˚C) -10~+50

 Hysteresis (%FS) 0.02

 Use Temp. (˚C) -20~+60

 Repeatability (%FS) 0.02/0.01

 Temp. Effect on Span(%FS) 0.02

 Creep (%FS) 0.03/0.02

Temp. Effect on Zero(%FS) 0.02

 Zero Balance (%FS) + 1.0

Safe Overload(%FS) 120

 Input Impedance(Ω) 400 + 10

 Ultimate Overload(%FS) 150

Bending Beam Load Cells

Request Callback

₹ 2200 / Piece Get Latest Price

Product Brochure
ModelKP-901
TypeBending Beam
MaterialStainless Steel
Ingress ProtectionIP68
ApplicationSmall Hopper-Tank
Capacity20,50,100,200
FeaturesHigh Accuracy & Precision, Hermetically sealed
Output Sensitivity(FS)2.0 +/- 0.002 mV/V
Combined Error0.001%
Creep Error (30 minutes)0.001%
Accuracy ClassOIML R60 C3
Temperature Effect on Zero0.001%
Zero balance+/- 1% FS
Maximum Safe Overload120% FS
Ultimate Safe Overload180% FS
Recommended Excitation Voltage9 to 12V DC
Maximum Excitation Voltage15V DC
Input Resistance390
Output Resistance350
Insulation resistance at 50V DC>= 10 G Ohm
Compensated Temperature Range-30 to +70 Deg C
Operating Temperatue Range-10 to +40 Deg C
Load Cell Intervals (nLC)/Divisions4000
Cable Length3 mtr
Bending Beam Load Cell with High AccuracyRATED LOAD (KG) 10, 20, 30, 50, 100, 200, 300, 500Precision C2/C3
Output Impedance(Ω) 350 + 5Composition Error 0.03/0.02
Insulation (MΩ) > 20000Rated Output(mv/v) 2.0 + 0.001
Excitation Voltage(V) 5~15(DC)Non-Linearity (%FS) 0.025
Compensated Temp.(˚C) -10~+50Hysteresis (%FS) 0.02
Use Temp. (˚C) -20~+60Repeatability (%FS) 0.02/0.01
Temp. Effect on Span(%FS) 0.02Creep (%FS) 0.03/0.02
Temp. Effect on Zero(%FS) 0.02Zero Balance (%FS) + 1.0
Safe Overload(%FS) 120Input Impedance(Ω) 400 + 10
Ultimate Overload(%FS) 150

Beam Type Load Cell

Request Callback

₹ 3200 / Piece Get Latest Price

ModelStandard
CapacityStandard
Cable LengthStandard
SizeStandard
WightStandard

RATED LOAD (KG) 10, 20, 30, 50, 100, 200, 300, 500

Precision C2/C3

Output Impedance(Ω) 350 + 5

 Composition Error 0.03/0.02

Insulation (MΩ) > 20000

Rated Output(mv/v) 3.0 + 0.2

 Excitation Voltage(V) 5~15(DC)

Non-Linearity (%FS) 0.025

Compensated Temp.(˚C) -10~+50

 Hysteresis (%FS) 0.02

 Use Temp. (˚C) -20~+60

 Repeatability (%FS) 0.02/0.01

 Temp. Effect on Span(%FS) 0.02

 Creep (%FS) 0.03/0.02

Temp. Effect on Zero(%FS) 0.02

 Zero Balance (%FS) + 1.0

Safe Overload(%FS) 120

 Input Impedance(Ω) 400 + 10

 Ultimate Overload(%FS) 150

X

Contact Us

HN Patel (Owner)
K.P.Automation & Control
161, Ved Industrial Park - 2, B/H Shreenath Estate Kathwada Road, Kathwada
Ahmedabad - 382430, Gujarat, India

Get Directions
Send Email
Share: